{"id":5170,"date":"2023-06-28T09:04:31","date_gmt":"2023-06-28T09:04:31","guid":{"rendered":"https:\/\/dizelsanat.com\/?post_type=product&#038;p=5170"},"modified":"2024-04-14T07:05:38","modified_gmt":"2024-04-14T07:05:38","slug":"e-line-mv-busbar","status":"publish","type":"product","link":"https:\/\/dizelsanat.com\/en\/product\/e-line-mv-busbar\/","title":{"rendered":"E-Line MV Busbar"},"content":{"rendered":"<h2>\u00a0E-Line MV Busbar<\/h2>\n<div style=\"text-align: center;\">\n<table border=\"1\" width=\"100%\">\n<thead>\n<tr>\n<td style=\"text-align: center;\" colspan=\"3\">\n<h3 class=\"tbk__title fs-xxl fw-thin\"><span class=\"fw-semibold fs-l fs-xs-xl tcolor\">Conductor Material and Rated Currents<\/span><\/h3>\n<\/td>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td style=\"text-align: center;\" bgcolor=\"#ffb200\">\n<h5>24KV<\/h5>\n<h5>Copper Conductor<\/h5>\n<h5><\/h5>\n<\/td>\n<td style=\"text-align: center;\" bgcolor=\"#ffb200\">\n<h5>12KV<\/h5>\n<h5>Copper Conductor<\/h5>\n<h5><\/h5>\n<\/td>\n<td style=\"text-align: center;\" bgcolor=\"#ffb200\">\n<h5>24KV<\/h5>\n<h5>Aluminum Conductor<\/h5>\n<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center;\">\n<p dir=\"ltr\">1800\/2100\/3200\/4000\/5000\/5700A<\/p>\n<\/td>\n<td style=\"text-align: center;\"><i class=\"fa fa-angle-right\"><\/i>\u00a0950\/1150\/1350\/1650\/2250\/2750A<\/td>\n<td style=\"text-align: center;\">1500 \/ 2000 \/ 2500 \/ 3000A<i class=\"fa fa-angle-right\"><\/i><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<h3><\/h3>\n<div class=\"woocommerce-product-details__short-description\">\n<p>&nbsp;<\/p>\n<div style=\"text-align: center;\">\n<table border=\"1\" width=\"100%\">\n<thead>\n<tr>\n<td style=\"text-align: center;\" colspan=\"2\">\n<h3>Copper Conductor (Cu)<\/h3>\n<\/td>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td style=\"text-align: center;\">IEC 62271-200 Edition 2.0 2011-10; IEC 62271-307 Edition 1.0 2015-09; IEC 61439-6 Edition 1.0 2012-05; STL Guide to IEC 62271-200<\/td>\n<td style=\"text-align: center;\">Standards<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center;\">Ur kV 12<\/td>\n<td style=\"text-align: center;\">Rated Voltage<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center;\">Ud kV 28<\/td>\n<td style=\"text-align: center;\">Rated power frequency withstand voltage<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center;\">Up kV 75<\/td>\n<td style=\"text-align: center;\">Rated impulse withstand withstand voltage<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center;\">f Hz 50<\/td>\n<td style=\"text-align: center;\">Rated Frequency<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center;\">50J, greater than IK10<\/td>\n<td style=\"text-align: center;\">External Mechanical Impacts (IK Code)*<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<p>&nbsp;<\/p>\n<table>\n<tbody>\n<tr>\n<th>Rated Current<\/th>\n<th>Busbar Code<\/th>\n<th>Phase Conductor<\/th>\n<th>PE<\/th>\n<th>Conductor Cross Section<\/th>\n<th>Busbar Weight (3 Conductors)<\/th>\n<\/tr>\n<tr>\n<th>A<\/th>\n<td><\/td>\n<td>mm\u00b2<\/td>\n<td>mm\u00b2<\/td>\n<td>\u00a0mm\u00b2<\/td>\n<td>kg\/m<\/td>\n<\/tr>\n<tr>\n<th>950<\/th>\n<td>09<\/td>\n<td>240<\/td>\n<td>5944<\/td>\n<td>40*6<\/td>\n<td>48.32<\/td>\n<\/tr>\n<tr>\n<th>1150<\/th>\n<td>11<\/td>\n<td>330<\/td>\n<td>5944<\/td>\n<td>55*6<\/td>\n<td>56.85<\/td>\n<\/tr>\n<tr>\n<th>1350<\/th>\n<td>13<\/td>\n<td>420<\/td>\n<td>5944<\/td>\n<td>70*6<\/td>\n<td>63.89<\/td>\n<\/tr>\n<tr>\n<th>1650<\/th>\n<td>16<\/td>\n<td>570<\/td>\n<td>8105<\/td>\n<td>95*6<\/td>\n<td>76.18<\/td>\n<\/tr>\n<tr>\n<th>2250<\/th>\n<td>22<\/td>\n<td>840<\/td>\n<td>8905<\/td>\n<td>140*6<\/td>\n<td>97.13<\/td>\n<\/tr>\n<tr>\n<th>2750<\/th>\n<td>27<\/td>\n<td>1200<\/td>\n<td>9704<\/td>\n<td>200*6<\/td>\n<td>124.54<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<div class=\"woocommerce-product-details__short-description\">\n<p>&nbsp;<\/p>\n<div style=\"text-align: center;\">\n<table border=\"1\" width=\"100%\">\n<thead>\n<tr>\n<td style=\"text-align: center;\" colspan=\"2\">\n<h3>Aluminium Conductor (Al)<\/h3>\n<\/td>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td style=\"text-align: center;\">IEC 62271-200 Edition 2.0 2011-10; IEC 61439-6 Edition 1.0 2012-05;<br \/>\nIEC 62271-307 Edition 1.0 2015-09; STL Guide to IEC 62271-200 Edition 2.0 2011-10<\/td>\n<td style=\"text-align: center;\">Standards<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center;\">Ur kV 24<\/td>\n<td style=\"text-align: center;\">Rated Voltage<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center;\">Ud kV 50<\/td>\n<td style=\"text-align: center;\">Rated power frequency withstand voltage<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center;\">Up kV 125<\/td>\n<td style=\"text-align: center;\">Rated impulse withstand withstand voltage<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center;\">f Hz 50\/60<\/td>\n<td style=\"text-align: center;\">Rated Frequency<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center;\">50J, &gt; IK10<\/td>\n<td style=\"text-align: center;\">External Mechanical Impacts (IK Code)*<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<p>&nbsp;<\/p>\n<table>\n<tbody>\n<tr>\n<th>Rated Current<\/th>\n<th>Busbar Code<\/th>\n<th>Phase Conductor<\/th>\n<th>PE<\/th>\n<th>Conductor Cross Section<\/th>\n<th>Busbar Weight (3 Conductors)<\/th>\n<\/tr>\n<tr>\n<th>A<\/th>\n<td><\/td>\n<td>mm\u00b2<\/td>\n<td>mm\u00b2<\/td>\n<td>\u00a0mm\u00b2<\/td>\n<td>kg\/m<\/td>\n<\/tr>\n<tr>\n<th>1500<\/th>\n<td>15<\/td>\n<td>525<\/td>\n<td>8515<\/td>\n<td>75*7<\/td>\n<td>95<\/td>\n<\/tr>\n<tr>\n<th>2000<\/th>\n<td>20<\/td>\n<td>1200<\/td>\n<td>8515<\/td>\n<td>100*12<\/td>\n<td>100<\/td>\n<\/tr>\n<tr>\n<th>2500<\/th>\n<td>25<\/td>\n<td>1800<\/td>\n<td>9394<\/td>\n<td>150*12<\/td>\n<td>120<\/td>\n<\/tr>\n<tr>\n<th>3000<\/th>\n<td>30<\/td>\n<td>2400<\/td>\n<td>10194<\/td>\n<td>200*12<\/td>\n<td>143<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<div class=\"woocommerce-product-details__short-description\">\n<p>&nbsp;<\/p>\n<div style=\"text-align: center;\">\n<table border=\"1\" width=\"100%\">\n<thead>\n<tr>\n<td style=\"text-align: center;\" colspan=\"2\">\n<h3>Copper Conductor (Cu)<\/h3>\n<\/td>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td style=\"text-align: center;\">IEC 62271-200 Edition 2.0 2011-10; IEC 61439-6 Edition 1.0 2012-05;<br \/>\nIEC 62271-307 Edition 1.0 2015-09; STL Guide to IEC 62271-200 Edition 2.0 2011-10<\/td>\n<td style=\"text-align: center;\">Standards<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center;\">Ur kV 24<\/td>\n<td style=\"text-align: center;\">Rated Voltage<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center;\">Ud kV 50<\/td>\n<td style=\"text-align: center;\">Rated power frequency withstand voltage<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center;\">Up kV 125<\/td>\n<td style=\"text-align: center;\">Rated impulse withstand withstand voltage<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center;\">f Hz 50<\/td>\n<td style=\"text-align: center;\">Rated Frequency<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center;\">50J, &gt; IK10<\/td>\n<td style=\"text-align: center;\">External Mechanical Impacts (IK Code)*<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<p>&nbsp;<\/p>\n<table>\n<tbody>\n<tr>\n<th>Rated Current<\/th>\n<th>Busbar Code<\/th>\n<th>Phase Conductor<\/th>\n<th>PE<\/th>\n<th>Conductor Cross Section<\/th>\n<th>Busbar Weight (3 Conductors)<\/th>\n<\/tr>\n<tr>\n<th>A<\/th>\n<td><\/td>\n<td>mm\u00b2<\/td>\n<td>mm\u00b2<\/td>\n<td>\u00a0mm\u00b2<\/td>\n<td>kg\/m<\/td>\n<\/tr>\n<tr>\n<th>1800<\/th>\n<td>18<\/td>\n<td>490<\/td>\n<td>8515<\/td>\n<td>70*7<\/td>\n<td>104<\/td>\n<\/tr>\n<tr>\n<th>2100<\/th>\n<td>21<\/td>\n<td>525<\/td>\n<td>8515<\/td>\n<td>75*7<\/td>\n<td>106<\/td>\n<\/tr>\n<tr>\n<th>3200<\/th>\n<td>32<\/td>\n<td>1200<\/td>\n<td>8515<\/td>\n<td>100*12<\/td>\n<td>122<\/td>\n<\/tr>\n<tr>\n<th>4000<\/th>\n<td>40<\/td>\n<td>1800<\/td>\n<td>9394<\/td>\n<td>150*12<\/td>\n<td>152<\/td>\n<\/tr>\n<tr>\n<th>5000<\/th>\n<td>50<\/td>\n<td>2400<\/td>\n<td>10194<\/td>\n<td>200*12<\/td>\n<td>187<\/td>\n<\/tr>\n<tr>\n<th>5700<\/th>\n<td>57<\/td>\n<td>3000<\/td>\n<td>10194<\/td>\n<td>200*15<\/td>\n<td>205<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<p style=\"text-align: left;\">To inquire about the price of all types of <a href=\"http:\/\/dizelsanat.com\/en\/product-category\/busduct\/\" target=\"_blank\" rel=\"noopener\"><strong class=\"uppercase\">Busduct <\/strong><\/a>, contact experts <a href=\"https:\/\/dizelsanat.com\/en\/contact-us\/\" target=\"_blank\" rel=\"noopener\">DizelSanat<\/a>.<\/p>\n","protected":false},"excerpt":{"rendered":"<h5>Aluminum Conductor:<\/h5>\n<p><i class=\"fa fa-angle-right\"><\/i>\u00a03 Conductor (L1\/L2\/L3\/PE Housing)<\/p>\n","protected":false},"featured_media":5172,"comment_status":"closed","ping_status":"closed","template":"","meta":[],"product_brand":[],"product_cat":[444],"product_tag":[],"class_list":{"0":"post-5170","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-busduct","8":"first","9":"instock","10":"taxable","11":"shipping-taxable","12":"product-type-simple"},"_links":{"self":[{"href":"https:\/\/dizelsanat.com\/en\/wp-json\/wp\/v2\/product\/5170","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/dizelsanat.com\/en\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/dizelsanat.com\/en\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/dizelsanat.com\/en\/wp-json\/wp\/v2\/comments?post=5170"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/dizelsanat.com\/en\/wp-json\/wp\/v2\/media\/5172"}],"wp:attachment":[{"href":"https:\/\/dizelsanat.com\/en\/wp-json\/wp\/v2\/media?parent=5170"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/dizelsanat.com\/en\/wp-json\/wp\/v2\/product_brand?post=5170"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/dizelsanat.com\/en\/wp-json\/wp\/v2\/product_cat?post=5170"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/dizelsanat.com\/en\/wp-json\/wp\/v2\/product_tag?post=5170"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}