{"id":5133,"date":"2023-06-27T07:00:55","date_gmt":"2023-06-27T07:00:55","guid":{"rendered":"https:\/\/dizelsanat.com\/?post_type=product&#038;p=5133"},"modified":"2024-04-14T07:10:37","modified_gmt":"2024-04-14T07:10:37","slug":"e-line-ko-ii-busbar","status":"publish","type":"product","link":"https:\/\/dizelsanat.com\/en\/product\/e-line-ko-ii-busbar\/","title":{"rendered":"E-Line KO-II Busbar"},"content":{"rendered":"<div style=\"text-align: center;\">\n<h1 style=\"text-align: left;\">E-Line KO-II Busbar<\/h1>\n<table border=\"1\" width=\"100%\">\n<thead>\n<tr>\n<td style=\"text-align: center;\" colspan=\"2\">\n<h3 class=\"tbk__title fs-xxl fw-thin\"><span class=\"fw-semibold fs-l fs-xs-xl tcolor\">Conductor Material and Rated Currents<\/span><\/h3>\n<\/td>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td style=\"text-align: center;\" bgcolor=\"#ffb200\">\n<h5><strong>Copper Conductor<\/strong><\/h5>\n<\/td>\n<td style=\"text-align: center;\" bgcolor=\"#ffb200\">\n<h5><strong>Aluminum Conductor<\/strong><\/h5>\n<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center;\">\n<p dir=\"ltr\">250A \/ 315A \/ 400A \/ 600A \/ 800A<\/p>\n<\/td>\n<td style=\"text-align: center;\">160A \/ 250A \/ 315A \/ 400A \/ 500A \/ 600A \/ 630A \/ 800A<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<div class=\"woocommerce-product-details__short-description\">\n<p>&nbsp;<\/p>\n<div style=\"text-align: center;\">\n<table border=\"1\" width=\"100%\">\n<thead>\n<tr>\n<td style=\"text-align: center;\" colspan=\"2\">\n<h3>Aluminium Conductor (KOA)<\/h3>\n<\/td>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td style=\"text-align: center;\">06 08 02 03 04 06 08<br \/>\nStandards IEC 61439-6, TS EN 61439-6, IEC 61439-1, TS EN 61439-1<\/td>\n<td style=\"text-align: center;\">Standards<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center;\">Ui V 1000<\/td>\n<td style=\"text-align: center;\">Rated Isolation Voltage<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center;\">Ue V\u00a0 1000<\/td>\n<td style=\"text-align: center;\">Max. Rated Operational Voltage<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center;\">Uimp kV 12<\/td>\n<td style=\"text-align: center;\">Rated Impulse Withstand Voltage<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center;\">f Hz 50<\/td>\n<td style=\"text-align: center;\">Rated Frequency<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center;\">III<\/td>\n<td style=\"text-align: center;\">Pollution Degree<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center;\">IP 55<\/td>\n<td style=\"text-align: center;\">Protection Degree<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center;\">Plug-in Busbar IK09<\/td>\n<td style=\"text-align: center;\">External Mechanical Impacts (IK Code)*<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center;\">Basic protection (HD 60364-4-41, clause A1)<\/td>\n<td style=\"text-align: center;\">\u062d\u0641\u0627\u0638\u062a \u0628\u0631\u0627\u06cc \u0627\u06cc\u0645\u0646\u06cc<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<p>&nbsp;<\/p>\n<table>\n<tbody>\n<tr>\n<th>Rated Current<\/th>\n<th>Busbar Code<\/th>\n<th>L1,L2,L3,N<\/th>\n<th>PE (4 \u00bd)<\/th>\n<th>PE (5 )<\/th>\n<th>Conductor Cross Section<\/th>\n<th>Busbar Weight (4 Conductors)<\/th>\n<th>Busbar Weight (5 Conductors)<\/th>\n<\/tr>\n<tr>\n<th>A<\/th>\n<td><\/td>\n<td>mm\u00b2<\/td>\n<td>mm\u00b2<\/td>\n<td>mm\u00b2<\/td>\n<td>mmxmm<\/td>\n<td>kg\/m<\/td>\n<td>kg\/m<\/td>\n<\/tr>\n<tr>\n<th>160<\/th>\n<td>01<\/td>\n<td>120<\/td>\n<td>60<\/td>\n<td>120<\/td>\n<td>583<\/td>\n<td>7<\/td>\n<td>7.3<\/td>\n<\/tr>\n<tr>\n<th>250<\/th>\n<td>02<\/td>\n<td>150<\/td>\n<td>75<\/td>\n<td>150<\/td>\n<td>593<\/td>\n<td>7.5<\/td>\n<td>8<\/td>\n<\/tr>\n<tr>\n<th>315<\/th>\n<td>03<\/td>\n<td>180<\/td>\n<td>90<\/td>\n<td>180<\/td>\n<td>603<\/td>\n<td>8<\/td>\n<td>8.7<\/td>\n<\/tr>\n<tr>\n<th>400<\/th>\n<td>04<\/td>\n<td>300<\/td>\n<td>150<\/td>\n<td>300<\/td>\n<td>643<\/td>\n<td>10<\/td>\n<td>11<\/td>\n<\/tr>\n<tr>\n<th>500<\/th>\n<td>05<\/td>\n<td>375<\/td>\n<td>187.5<\/td>\n<td>375<\/td>\n<td>668<\/td>\n<td>11<\/td>\n<td>12<\/td>\n<\/tr>\n<tr>\n<th>600<\/th>\n<td>06<\/td>\n<td>450<\/td>\n<td>225<\/td>\n<td>450<\/td>\n<td>693<\/td>\n<td>12<\/td>\n<td>13<\/td>\n<\/tr>\n<tr>\n<th>800<\/th>\n<td>08<\/td>\n<td>660<\/td>\n<td>330<\/td>\n<td>660<\/td>\n<td>730<\/td>\n<td>15.1<\/td>\n<td>17<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<div class=\"woocommerce-product-details__short-description\">\n<p>&nbsp;<\/p>\n<div style=\"text-align: center;\">\n<table border=\"1\" width=\"100%\">\n<thead>\n<tr>\n<td style=\"text-align: center;\" colspan=\"2\">\n<h3>Copper Conductor (KOC)<\/h3>\n<\/td>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td style=\"text-align: center;\">Standards IEC 61439-6, TS EN 61439-6, IEC 61439-1, TS EN 61439-1<\/td>\n<td style=\"text-align: center;\">Standards<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center;\">Ui V 1000<\/td>\n<td style=\"text-align: center;\">Rated Isolation Voltage<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center;\">Ue V\u00a0 1000<\/td>\n<td style=\"text-align: center;\">Max. Rated Operational Voltage<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center;\">Uimp kV 12<\/td>\n<td style=\"text-align: center;\">Rated Impulse Withstand Voltage<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center;\">f Hz 50<\/td>\n<td style=\"text-align: center;\">Rated Frequency<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center;\">III<\/td>\n<td style=\"text-align: center;\">Pollution Degree<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center;\">IP 55<\/td>\n<td style=\"text-align: center;\">Protection Degree<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center;\">Plug-in Busbar IK09<\/td>\n<td style=\"text-align: center;\">External Mechanical Impacts (IK Code)*<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center;\">Basic protection (HD 60364-4-41, clause A1)<\/td>\n<td style=\"text-align: center;\">\u062d\u0641\u0627\u0638\u062a \u0628\u0631\u0627\u06cc \u0627\u06cc\u0645\u0646\u06cc<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<p>&nbsp;<\/p>\n<table>\n<tbody>\n<tr>\n<th>Rated Current<\/th>\n<th>Busbar Code<\/th>\n<th>L1,L2,L3,N<\/th>\n<th>PE (4 \u00bd)<\/th>\n<th>PE (5 )<\/th>\n<th>Conductor Cross Section<\/th>\n<th>Busbar Weight (4 Conductors)<\/th>\n<th>Busbar Weight (5 Conductors)<\/th>\n<\/tr>\n<tr>\n<th>A<\/th>\n<td><\/td>\n<td>mm\u00b2<\/td>\n<td>mm\u00b2<\/td>\n<td>mm\u00b2<\/td>\n<td>mmxmm<\/td>\n<td>kg\/m<\/td>\n<td>kg\/m<\/td>\n<\/tr>\n<tr>\n<th>250<\/th>\n<td>02<\/td>\n<td>120<\/td>\n<td>60<\/td>\n<td>120<\/td>\n<td>583<\/td>\n<td>10<\/td>\n<td>11<\/td>\n<\/tr>\n<tr>\n<th>315<\/th>\n<td>03<\/td>\n<td>150<\/td>\n<td>75<\/td>\n<td>150<\/td>\n<td>593<\/td>\n<td>11<\/td>\n<td>12.5<\/td>\n<\/tr>\n<tr>\n<th>400<\/th>\n<td>04<\/td>\n<td>180<\/td>\n<td>90<\/td>\n<td>180<\/td>\n<td>603<\/td>\n<td>12.5<\/td>\n<td>14<\/td>\n<\/tr>\n<tr>\n<th>600<\/th>\n<td>06<\/td>\n<td>300<\/td>\n<td>150<\/td>\n<td>300<\/td>\n<td>643<\/td>\n<td>16<\/td>\n<td>19<\/td>\n<\/tr>\n<tr>\n<th>800<\/th>\n<td>08<\/td>\n<td>450<\/td>\n<td>225<\/td>\n<td>450<\/td>\n<td>693<\/td>\n<td>18<\/td>\n<td>21<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<p style=\"text-align: left;\">To inquire about the price of all types of <a href=\"http:\/\/dizelsanat.com\/en\/product-category\/busduct\/\" target=\"_blank\" rel=\"noopener\"><strong class=\"uppercase\">Busduct <\/strong><\/a>, contact experts <a href=\"https:\/\/dizelsanat.com\/en\/contact-us\/\" target=\"_blank\" rel=\"noopener\">DizelSanat<\/a>.<\/p>\n","protected":false},"excerpt":{"rendered":"<div class=\"kl-title-block\">\n<h3 class=\"tbk__title fs-xxl fw-thin\"><span class=\"fw-semibold fs-l fs-xs-xl tcolor\">Conductor Configuration<\/span><\/h3>\n<\/div>\n<div>\n<h5 class=\"product-h5 mb-0\">Aluminium or Copper Conductor:<\/h5>\n<ul>\n<li><i class=\"fa fa-angle-right\"><\/i>\u00a04 Conductor (L1\/L2\/L3\/N\/ PE Housing)<\/li>\n<li><i class=\"fa fa-angle-right\"><\/i>\u00a04 \u00bd Conductor (L1\/L2\/L3\/N\/ \u00bd PE \/ PE Housing)<\/li>\n<li><i class=\"fa fa-angle-right\"><\/i>\u00a04 \u00bd Conductor (L1\/L2\/L3\/N\/ \u00bd PE \/ CPE Housing) \u2013 Clean Earth<\/li>\n<li><i class=\"fa fa-angle-right\"><\/i>\u00a05 Conductor (L1\/L2\/L3\/N\/ PE \/ PE Housing)<\/li>\n<li><i class=\"fa fa-angle-right\"><\/i>\u00a05 Conductor (L1\/L2\/L3\/N\/ \u00bd CPE \/ PE Housing) \u2013 Clean Earth<\/li>\n<\/ul>\n<\/div>\n<p>&nbsp;<\/p>\n<p><span class=\"Y2IQFc\" lang=\"en\">Download Catalog :<\/span><\/p>\n<p><a href=\"https:\/\/dizelsanat.com\/wp-content\/uploads\/2023\/06\/e-line-ko-ii-busbar.pdf\">E-Line KO-II Busbar<\/a><\/p>\n","protected":false},"featured_media":5163,"comment_status":"closed","ping_status":"closed","template":"","meta":[],"product_brand":[],"product_cat":[444],"product_tag":[],"class_list":{"0":"post-5133","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-busduct","8":"first","9":"instock","10":"taxable","11":"shipping-taxable","12":"product-type-simple"},"_links":{"self":[{"href":"https:\/\/dizelsanat.com\/en\/wp-json\/wp\/v2\/product\/5133","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/dizelsanat.com\/en\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/dizelsanat.com\/en\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/dizelsanat.com\/en\/wp-json\/wp\/v2\/comments?post=5133"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/dizelsanat.com\/en\/wp-json\/wp\/v2\/media\/5163"}],"wp:attachment":[{"href":"https:\/\/dizelsanat.com\/en\/wp-json\/wp\/v2\/media?parent=5133"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/dizelsanat.com\/en\/wp-json\/wp\/v2\/product_brand?post=5133"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/dizelsanat.com\/en\/wp-json\/wp\/v2\/product_cat?post=5133"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/dizelsanat.com\/en\/wp-json\/wp\/v2\/product_tag?post=5133"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}